| รหัสสินค้า | SKU-02741 | 
| หมวดหมู่ | Limit Switch / ลิมิตสวิทช์ | 
| ราคา | 1,200.00 บาท | 
| สถานะสินค้า | พร้อมส่ง | 
| ลงสินค้า | 14 มี.ค. 2567 | 
| อัพเดทล่าสุด | 14 มี.ค. 2567 | 
| คงเหลือ | 2 ชิ้น | 
| จำนวน | ชิ้น  | 
Shape / Structure  | 
General-purpose Limit switches | 
|---|---|
| service life | General type | 
| Operating mechanism | Snap action | 
| Actuator | Roller lever (Over travel 80 DEG, 17.5 dia. * 7, Sintered stainless steel roller, 38 R) | 
| Frequency | 50/60 Hz | 
| Leakage current | Approx. 0.5 mA | 
| Switching mechanism | Self-reset mechanism | 
| Contact configuration | 2-circuit double break type | 
| Contact form | SPST-NO / SPST-NC | 
| Load | General load | 
| Ratings (AC): Non-Inductive load | Rated voltage: 115 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) | 
| Ratings (AC): Inductive load | Rated voltage: 115 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A (NC) 2.5 A (NO) | 
| Ratings (DC): Non-Inductive load | Rated voltage: 12 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 6 A (NC) 3 A (NO) Rated voltage: 24 VDC, Resistive load: 6 A (NC) 6 A (NO), Lamp load: 4 A (NC) 3 A (NO) Rated voltage: 48 VDC, Resistive load: 3 A (NC) 3 A (NO), Lamp load: 2 A (NC) 1.5 A (NO) Rated voltage: 115 VDC, Resistive load: 0.8 A (NC) 0.8 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO)  | 
| Ratings (DC): Inductive load | Rated voltage: 12 VDC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 6 A (NC) 6 A (NO) Rated voltage: 24 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load: 4 A (NC) 4 A (NO) Rated voltage: 48 VDC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 2 A (NC) 2 A (NO) Rated voltage: 115 VDC, Inductive load: 0.8 A (NC) 0.8 A (NO), Motor load: 0.2 A (NC) 0.2 A (NO)  | 
| Explanation | The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. | 
| Inrush current | NC: 30 A NO: 20 A  | 
| Indicator | LED (Possible to change between Light when operating and Light when not operating.) Voltage: Common use for AC/DC 10 to 115 V Leakage current: Approx. 0.5 mA  | 
| Conduit size | G1/2 | 
| Earth terminal | Without ground terminal | 
| Ambient temperature | Operating: -10 to 80 CEL (with no icing or condensation)  | 
| Ambient humidity | Operating: 35 to 95%RH (with no icing or condensation)  | 
| Permissible operating speed | 1 mm/s to 1 m/s | 
|---|---|
| Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. | 
| Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. | 
| Contact resistance | 25 mOhm Max. (Initial value) (Measuring method is contact resistance meter.)  | 
| Insulation resistance | Between live-metallic part and ground: 100 MOhm Min. Between each terminal and non-live-metallic part: 100 MOhm Min. (Without LED, at 500 VDC Megger)  | 
| Dielectric strength | Between live-metallic part and ground: 2,200 VAC Between each terminal and non-live-metallic part: 2,200 VAC (50/60 Hz for 1 min, Without LED)  | 
| Durability (Mechanically) | 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)  | 
| Durability (Electrically) | 750,000 operations Min. (Resistive load 10 A at 115 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)  | 
| Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. | 
| Shock resistance (Destruction) | 1,000 m/s2 | 
| Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. | 
| Degree of protection | IEC60529 (JEM): IP67 NEMA250: Type3, 4, 13  | 
| Applicable standard (UL) | Standard No.: UL508 File number: E76675  | 
| Applicable standard (CSA) | Standard No.: C22.2 NO.14 File number: LR45746  | 
| Applicable standard (CCC(CQC)) | Standard No.: GB14048.5 File number: 2004010305128675  | 
| Mounting specification | Front mounting, Back mounting | 
| Operating Force (OF) | Standard value 9.81 N Max. | 
|---|---|
| Release Force (RF) | Standard value 0.98 N Min. | 
| Pre-Travel (PT) | Standard value 15 +/- 5 DEG | 
| Over-Travel (OT) | Standard value 55 DEG Min. | 
| Movement Differential (MD) | Standard value 12 DEG Max. | 



นโยบายการรับเปลี่ยน
1.ร้านยินดีรับเปลี่ยนสินค้า ภายใน 7 วันทำการนับตั้งแต่ลูกค้าเซ็นต์รับสินค้านั้นแล้วหากเกินจากวันเวลาดังกล่าวแล้ว บริษัทฯ ขอสงวนสิทธิ์ในการไม่รับเปลี่ยน/คืนสินค้า
2.ลูกค้าสามารถขอเปลี่ยน/คืนสินค้าโดยลูกค้าจะต้องทำการจัดส่งสินค้ากลับมายังบริษัทฯโดยที่สินค้าที่ลูกค้าต้องการเปลี่ยน/คืนจะต้องอยู่ในสภาพสมบูรณ์ ไม่ชำรุดเสียหายจากการใช้งาน
สภาพสินค้าต้องไม่เกิดการเปลี่ยนแปลงใดๆ รวมถึงป้ายราคา ป้ายยี่ห้อสินค้า เอกสารคู่มือต่างๆยังคงอยู่ และบรรจุ ในหีบห่อบรรจุภัณฑ์ของสินค้านั้นๆ ในสภาพเดียวกันกับสภาพที่บริษัทฯ นำส่งต่อลูกค้าพร้อมแสดงหลักฐานในการสั่งซื้อสินค้า
ซึ่งลูกค้าสามารถเปลี่ยน/คืนสินค้าตามกรณีดังต่อไปนี้
2.1 จัดส่งสินค้าผิดรุ่น ผิดสี หรือผิดขนาด ให้กับลูกค้า อ้างอิงตามหลักฐานใบสั่งซื้อ
2.2 จัดส่งสินค้าที่มีลักษณะแตกต่าง หรือไม่มีส่วนคล้ายคลึงกับรูปภาพของสินค้าที่ได้แสดงไว้ในหน้ารายละเอียดสินค้า
2.3 จัดส่งสินค้าที่มีสภาพชำรุด เสียหาย หรือไม่สามารถใช้งานได้ตั้งแต่ได้รับสินค้า ให้กับลูกค้า ทางร้านจะแจ้งสภาพให้ก่อนตกลงสั่งซื้อ

นี่คือกล่อง "เขียนข้อความ" กล่องที่จะให้คุณเพิ่มข้อความ รูปภาพและวิดีโอได้อย่างอิสระตามสไตล์ของคุณเอง เช่น แบนเนอร์ โปรโมชั่น บทความ แนะนำร้านค้า หรือ รายการสินค้าเด่น เป็นต้น โดยคุณสามารถแก้ไขหรือลบกล่องนี้ได้หากคุณต้องการ ซึ่งมีวิธีการตามขั้นตอนดังต่อไปนี้
วิธีการแก้ไขข้อความในกล่อง
เข้าสู่โหมดตกแต่งร้าน > คลิกเลือกที่กล่องนี้ > เลือกเมนูข้อความ

| หน้าที่เข้าชม | 949,548 ครั้ง | 
| ผู้ชมทั้งหมด | 629,217 ครั้ง | 
| เปิดร้าน | 17 ม.ค. 2559 | 
| ร้านค้าอัพเดท | 4 พ.ย. 2568 | 
			สยามออโตเมชั่น