| รหัสสินค้า | SKU-00876 |
| หมวดหมู่ | Circuit Breaker , Magnetic Contactor |
| ราคา | 1,700.00 บาท |
| สถานะสินค้า | พร้อมส่ง |
| ลงสินค้า | 6 ต.ค. 2560 |
| อัพเดทล่าสุด | 19 ม.ค. 2565 |
| คงเหลือ | 1 ชิ้น |
| จำนวน | ชิ้น |
| range of product |
TeSys D
|
|
| range |
TeSys
|
|
| product name |
TeSys D
|
|
| product or component type |
Contactor
|
|
| device short name |
LC1D
|
|
| contactor application |
Resistive load
Motor control |
|
| utilisation category |
AC-4
AC-3 AC-1 |
|
| poles description |
3P
|
|
| pole contact composition |
3 NO
|
|
| System Voltage |
<= 300 V DC power circuit
<= 690 V AC 25...400 Hz power circuit |
|
| [Ie] rated operational current |
18 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit
32 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit |
|
| motor power kW |
10 kW at 500 V AC 50/60 Hz AC-3
10 kW at 660...690 V AC 50/60 Hz AC-3 4 kW at 220...230 V AC 50/60 Hz AC-3 7.5 kW at 380...400 V AC 50/60 Hz AC-3 9 kW at 415...440 V AC 50/60 Hz AC-3 4 kW at 400 V AC 50/60 Hz AC-4 |
|
| motor power hp |
1 hp at 115 V AC 50/60 Hz 1 phase motors
3 hp at 230/240 V AC 50/60 Hz 1 phase motors 5 hp at 200/208 V AC 50/60 Hz 3 phases motors 5 hp at 230/240 V AC 50/60 Hz 3 phases motors 10 hp at 460/480 V AC 50/60 Hz 3 phases motors 15 hp at 575/600 V AC 50/60 Hz 3 phases motors |
|
| control circuit type |
DC standard
|
|
| [Uc] control circuit voltage |
24 V DC
|
|
| auxiliary contact composition |
1 NO + 1 NC
|
|
| [Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947
|
|
| overvoltage category |
III
|
|
| [Ith] conventional free air thermal current |
32 A at <= 140 °F (60 °C) power circuit
10 A at <= 140 °F (60 °C) signalling circuit |
|
| Irms rated making capacity |
300 A at 440 V power circuit conforming to IEC 60947
140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 |
|
| rated breaking capacity |
300 A at 440 V power circuit conforming to IEC 60947
|
|
| [Icw] rated short-time withstand current |
145 A <= 104 °F (40 °C) 10 s power circuit
240 A <= 104 °F (40 °C) 1 s power circuit 40 A <= 104 °F (40 °C) 10 min power circuit 84 A <= 104 °F (40 °C) 1 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit |
|
| associated fuse rating |
35 A gG at <= 690 V coordination type 2 power circuit
50 A gG at <= 690 V coordination type 1 power circuit 10 A gG signalling circuit conforming to IEC 60947-5-1 |
|
| average impedance |
2.5 mOhm at 50 Hz - Ith 32 A power circuit
|
|
| [Ui] rated insulation voltage |
600 V power circuit certifications CSA
600 V power circuit certifications UL 690 V power circuit conforming to IEC 60947-4-1 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL |
|
| electrical durability |
1.65 Mcycles 18 A AC-3 at Ue <= 440 V
1 Mcycles 32 A AC-1 at Ue <= 440 V |
|
| power dissipation per pole |
0.8 W AC-3
2.5 W AC-1 |
|
| protective cover |
With
|
|
| mounting support |
Rail
Plate |
|
| standards |
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
|
| product certifications |
LROS (Lloyds register of shipping)
BV GOST DNV CCC GL CSA UL RINA |
|
| connections - terminals |
Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - without cable end Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - without cable end Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness: solid - without cable end Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness: solid - without cable end |
|
| tightening torque |
Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 |
|
| operating time |
53.55...72.45 ms closing
16...24 ms opening |
|
| safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
|
| mechanical durability |
30 Mcycles
|
|
| operating rate |
3600 cyc/h at <= 140 °F (60 °C)
|
S I A M A U T O M A T I O N
เปิดทำการวันจันทร์-ศุกร์ เวลา 8.30 - 16.30 น.


นโยบายการรับเปลี่ยน
1.ร้านยินดีรับเปลี่ยนสินค้า ภายใน 7 วันทำการนับตั้งแต่ลูกค้าเซ็นต์รับสินค้านั้นแล้วหากเกินจากวันเวลาดังกล่าวแล้ว บริษัทฯ ขอสงวนสิทธิ์ในการไม่รับเปลี่ยน/คืนสินค้า
2.ลูกค้าสามารถขอเปลี่ยน/คืนสินค้าโดยลูกค้าจะต้องทำการจัดส่งสินค้ากลับมายังบริษัทฯโดยที่สินค้าที่ลูกค้าต้องการเปลี่ยน/คืนจะต้องอยู่ในสภาพสมบูรณ์ ไม่ชำรุดเสียหายจากการใช้งาน
สภาพสินค้าต้องไม่เกิดการเปลี่ยนแปลงใดๆ รวมถึงป้ายราคา ป้ายยี่ห้อสินค้า เอกสารคู่มือต่างๆยังคงอยู่ และบรรจุ ในหีบห่อบรรจุภัณฑ์ของสินค้านั้นๆ ในสภาพเดียวกันกับสภาพที่บริษัทฯ นำส่งต่อลูกค้าพร้อมแสดงหลักฐานในการสั่งซื้อสินค้า
ซึ่งลูกค้าสามารถเปลี่ยน/คืนสินค้าตามกรณีดังต่อไปนี้
2.1 จัดส่งสินค้าผิดรุ่น ผิดสี หรือผิดขนาด ให้กับลูกค้า อ้างอิงตามหลักฐานใบสั่งซื้อ
2.2 จัดส่งสินค้าที่มีลักษณะแตกต่าง หรือไม่มีส่วนคล้ายคลึงกับรูปภาพของสินค้าที่ได้แสดงไว้ในหน้ารายละเอียดสินค้า
2.3 จัดส่งสินค้าที่มีสภาพชำรุด เสียหาย หรือไม่สามารถใช้งานได้ตั้งแต่ได้รับสินค้า ให้กับลูกค้า ทางร้านจะแจ้งสภาพให้ก่อนตกลงสั่งซื้อ

นี่คือกล่อง "เขียนข้อความ" กล่องที่จะให้คุณเพิ่มข้อความ รูปภาพและวิดีโอได้อย่างอิสระตามสไตล์ของคุณเอง เช่น แบนเนอร์ โปรโมชั่น บทความ แนะนำร้านค้า หรือ รายการสินค้าเด่น เป็นต้น โดยคุณสามารถแก้ไขหรือลบกล่องนี้ได้หากคุณต้องการ ซึ่งมีวิธีการตามขั้นตอนดังต่อไปนี้
วิธีการแก้ไขข้อความในกล่อง
เข้าสู่โหมดตกแต่งร้าน > คลิกเลือกที่กล่องนี้ > เลือกเมนูข้อความ

| หน้าที่เข้าชม | 957,285 ครั้ง |
| ผู้ชมทั้งหมด | 636,954 ครั้ง |
| เปิดร้าน | 17 ม.ค. 2559 |
| ร้านค้าอัพเดท | 11 ธ.ค. 2568 |
สยามออโตเมชั่น